Laser endoscope/software combo gives 3-D view of the bladder
Researchers at the University of Washington (UW; Seattle, WA) have created an automated approach to bladder cancer diagnosis using software in combination with an ultrathin endoscope that contains low-power lasers, enabling it to detect newly approved diagnostic cancer-cell markers. Seeking to create a less expensive, more comfortable, and more convenient method for doctors and patients alike, the combo pieces the images together from the endoscopeâs path to create a full, 3-D panorama of the bladder interiorâa procedure that could be done by a nurse or technician, avoiding the need for anesthesia. Resulting images could then be reviewed by a urologist at a later time, even in another location.
The current user interface projects the reconstructed organ onto a spherical ball or onto a flat map. The resulting mosaic matches the images to a single pixel of accuracyâgiving urologists "a Google Earth view of the bladder," says co-author Timothy Soper, a UW research scientist in mechanical engineering. Ultimately, the digital display would incorporate all the original frames, so a doctor could zoom in on an area of interest and observe from all angles at the highest resolution. Reviewing the resulting panoramic image would likely require less of the urologistâs time than performing a manual inspection.
Dr. Michael Porter, a UW assistant professor of urology, presented the software and the user interface, as well as preliminary results of 3-D panoramas from a commercially available endoscope inserted into a painted glass bulb, a stained pig bladder and a normal human bladder, at the annual meeting of the American Urological Association held last week in Washington, DC.
The UW software could be used with any endoscope, though the team sees particular benefit in combining it with its flexible endoscope, which measures 1.5 mm wide. A design that swings a single optical fiber back and forth to scan a color image pixel by pixel makes its tiny size possible. The UW endoscope's tip will contain a steering mechanism that directs the movement of the scope during the internal exam.
UW is awaiting FDA safety clearance to test the scope for human bladder scans and pursuing funding options. The next step will ask urologists to compare their experience of performing a diagnosis from a live video scan of a human bladder with the 3-D digital recreation.
A grant from the Wallace H. Coulter Foundation in the UWâs Department of Bioengineering, and by the UWâs Center for Commercialization, supported this work.
-----