Fluorescence microscopy approach captures three views of a sample simultaneously

Aug. 11, 2016
A new fluorescence microscopy approach improves image resolution by acquiring three views of a sample at the same time.

Researchers at the National Institute of Biomedical Imaging and Bioengineering (NIBIB) of the National Institutes of Health (NIH; Bethesda, MD) and collaborators have developed a new fluorescence microscopy approach that significantly improves image resolution by acquiring three views of a sample at the same time. Their new method is particularly useful for watching the dynamics of biological processes, which can provide insights into how healthy cells work and what goes wrong when diseases occur.

Related: Two views at once: Combined imaging boosts biomedical research

The researchers apply their multi-view technique in two microscopy modes and use it to image several types of biological samples. For both modes, the researchers demonstrated a volumetric resolution of up to 235 × 235 × 340 nm, which is double the volumetric resolution of traditional methods. Most current fluorescence microscopy methods fail to capture much of the fluorescence emitted from the sample, representing lost information and reduced image resolution.

"In our work, we captured this previously neglected fluorescence and fused it with the traditional views used in conventional microscopy," says Yicong Wu, NIBIB staff scientist and first author of a paper describing the work. "This increases resolution without compromising either temporal resolution or adding additional light to the sample."

The new multi-view approach helps improve a technique the researchers previously developed called dual-view selective-plane illumination microscopy (diSPIM). Scientists around the world employ commercial versions of diSPIM, which uses a thin sheet of light and two objectives lenses to excite and detect fluorescence.

"The main motivation of this new research was that the resolution in diSPIM was limited by the numerical aperture of the upper lenses, and fluorescence emitted in the direction of the coverslip is not captured," explains Hari Shroff, leader of the research team. "We reasoned that if we could simultaneously image this neglected signal by adding a higher numerical aperture lens that acquired the bottom view, then we could boost the lateral resolution."

In the improved diSPIM microscopy technique, each light sheet is tilted at a 45° angle relative to an additional lower objective lens. In its current design, the researchers swept the lower objective's plane of focus through the sample to image the previously unused fluorescence, but this mechanical scanning could be replaced with a passive optic in future versions of the microscope. Using the multi-view approach improved the lateral (horizontal) resolution of diSPIM to about 235 nm.

By adding a third objective lens, researchers were able to capture previously neglected fluorescence, improving image resolution in three dimensions. The schematic shows the new approach as applied to a type of light-sheet microscopy. (Credit: Yicong Wu, National Institute of Biomedical Imaging and Bioengineering)

The researchers also implemented the new technique in wide-field mode by scanning the three objectives through a sample simultaneously to produce three individual 3D views. With this mode, the multi-view method improved axial (z-axis) resolution to about 340 nm, an increase of 45%.

Whether acquired in wide-field or light-sheet mode, the three views must be precisely aligned and also cleaned up with an image processing technique known as deconvolution.

"One helpful trick was to deconvolve each view first to increase image quality, contrast, and so forth, which then allowed accurate registration of the three views," said Wu. "In wide-field mode, we further aided registration of the images by adding fluorescent beads to the samples as point of reference." He added that collaboration with Patrick La Riviere's research group at the University of Chicago (Illinois) was essential in thinking through and testing this deconvolution method.

The researchers demonstrated the multi-view technique by imaging biological samples and were able to see detailed features not typically observable. For example, the wide-field multi-view microscope clearly resolved the spherical protein shell present when Bacillus subtilis forms a spore and also allowed the researchers to observe the dynamics of organelles inside cells. In light-sheet mode, they clearly saw the 3D dynamic nature of tiny protrusions on living white blood cells when they acquired 150 triple-view images over 40 minutes.

Although other methods have been used to capture multiple views sequentially, this new method improves spatial resolution without introducing additional illumination or compromising temporal resolution relative to conventional imaging. This is important because additional light can be damaging—even deadly—to living cells, and the temporal resolution is needed to capture fast processes.

The research team is now exploring additional biological applications for the new system and is working to extend the method to other microscope modalities, such as confocal microscopy.

Full details of the work appear in the journal Optica; for more information, please visit http://dx.doi.org/10.1364/optica.3.000897.

About the Author

BioOptics World Editors

We edited the content of this article, which was contributed by outside sources, to fit our style and substance requirements. (Editor’s Note: BioOptics World has folded as a brand and is now part of Laser Focus World, effective in 2022.)

Sponsored Recommendations

Optical Power Meters for Diverse Applications

April 30, 2024
Bench-top single channel to multichannel power meters, Santec has the power measurement platforms to meet your requirements.

Request a quote: Micro 3D Printed Part or microArch micro-precision 3D printers

April 11, 2024
See the results for yourself! We'll print a benchmark part so that you can assess our quality. Just send us your file and we'll get to work.

Request a Micro 3D Printed Benchmark Part: Send us your file.

April 11, 2024
See the results for yourself! We'll print a benchmark part so that you can assess our quality. Just send us your file and we'll get to work.

Request a free Micro 3D Printed sample part

April 11, 2024
The best way to understand the part quality we can achieve is by seeing it first-hand. Request a free 3D printed high-precision sample part.

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!