• Super-resolution microscopy tracks single molecules in 3D with nanoscale accuracy

    New super-resolution microscopy work demonstrates a marked improvement in tracking molecules in three dimensions.
    Nov. 27, 2015
    4 min read

    Stanford University (CA) researchers, led by W. E. Moerner, have extended the work that earned Moerner and colleagues Eric Betzig and Stefan W. Hell the 2014 Nobel Prize for Chemistry. Betzig and Moerner pioneered the development of super-resolution microscopy, which broke the diffraction limit of optical microscopy by using the fluorescence of single molecules for the first time. The new work demonstrates a marked improvement in the accuracy of this imaging technique and for tracking molecules in three dimensions.

    Related: Nobel Prize honors super-resolution microscopy pioneers

    Tracking how molecules move, form shapes, and interact within the body's cells and neurons offers a powerful new view of key biological processes such as signaling, cell division, and neuron communication, all of which impact people's health and susceptibility to disease.

    Super-resolution microscopy uses lasers to excite fluorescence from single molecules under conditions where only a few are emitting at a time, overcoming the traditional resolution limit for optical microscopy set by the diffraction limit of light.

    "With the advent of super-resolution imaging, we improved the resolution by a factor of 5 to 10 beyond the diffraction limit—from 200 nm down to 40 or even 10 nm," Moerner said. "This new world of greatly increased resolution brings a big transformation in how the optical system works."

    However, previous calibration techniques for super-resolution microscopy were not sufficiently accurate for 3D measurements of single molecules. The new calibration method uses a nanohole array to correct for optical distortions across a widefield microscope's entire field of view.

    When imaging at the scale of single molecules, a single point of light coming from a molecule can typically be located with around 10 nm precision. At such high resolutions, any small imperfections in an optical system introduce image distortions, or aberrations, which can significantly skew measurements, particularly in 3D. The resulting errors could mean the difference between interpreting two molecules as interacting or simply being close to each other.

    While many use fluorescent beads to calibrate 3D microscopes, Alex von Diezmann, doctoral candidate at the Moerner Lab at Stanford University, took a different approach. He created an array of holes in a metal film, each smaller than 200 nm and regularly spaced 2.5 µm apart, to use as a 3D calibration standard. Once the holes were filled with fluorescent dyes, the array could be used to calibrate for optical errors across the microscope's entire field of view, not just at a few select spots, as is possible using fluorescent beads. Using this technique, the researchers were able to correct aberrations of 50–100 nm to just 25 nm.

    "Prior to this, people had not explicitly worried about these aberrations," von Diezmann says. "The fact that we demonstrated the presence of field-dependent aberrations, and showed that they could degrade images, is an important part of this work."

    The researchers studied the new calibration technique with double-helix and astigmatic point spread functions, two types of optical modification typically used to extract z-axis location. Although both point-spread functions showed z-axis related inaccuracies that created about a 20% error in the 3D measurements, the researchers corrected these aberrations using the 3D nanohole array.

    The researchers are now applying the new 3D calibration technique to all their single-molecule tracking and super-resolution microscopy studies. For example, von Diezmann is using it to study protein localization in bacteria that measure only 2 µm in length. With the 3D calibration technique, he can accurately measure and track key signaling proteins in nanodomains that are only 150–200 nm in size.

    The researchers point out that correcting field-dependent and other types of aberrations is becoming more and more important as optical microscopy techniques evolve to image deeper into cells, for example.

    "We studied this approach for a couple of cases, but it can be used with any super-resolution or localization microscopy that requires really precise 3D measurements," said von Diezmann. "It will be exciting to see other groups use it to figure out how their particular technique is affected by field-dependent aberrations. As a community, maybe we can find even better ways of dealing with these aberrations."

    Full details of the work appear in the journal Optica; for more information, please visit http://dx.doi.org/10.1364/optica.2.000985.