Radiometer from Gigahertz-Optik offers external TTL trigger input

Oct. 1, 2010
The handheld P-9710-4 radiometer/photometer has an external TTL trigger input for remote timing of pulsed light measurements.

The handheld P-9710-4 radiometer/photometer has an external TTL trigger input for remote timing of pulsed light measurements. It measures pulse energy (joules, J/cm2, lux-seconds, effective candela) of single and multiple burst pulsed events >1 ms long. System bandwidth is 0.166 Hz (at 6 s) to >300 MHz within the measurement range of 0.1 pA to 2 mA.
Gigahertz-Optik
Newburyport, MA

www.light-measurement.com

More Products

-----

PRESS RELEASE

UV-VIS-NIR PULSED LIGHT METER WITH EXTERNAL TRIGGER INPUT
Gigahertz-Optik’s hand-held P-9710-4 radiometer / photometer now features an external TTL trigger input function useful for remote timing of pulsed light measurements. In the P-9710-4 pulse energy mode, the measurement begins automatically upon the trigger input.

The P-9710-4 is capable of measuring the pulse energy (joules, J/cm2, lux-seconds, effective candela) of single and multiple burst pulsed events >1 microsecond in length. Stepped auto-ranging allows the user to zoom-in on the correct gain level with the last setting stored for future use. Independent of signal magnitude, system bandwidth is 0.166 Hz (at 6s) to > 300 MHz within the unit’s current measurement range of 0.1 pA to 2 mA.

Fifteen other menu selectable modes of operation including CW, dose, RS232 remote control plus internal datalogger function and AC or rechargeable battery power qualify the compact P-9710-4 for laboratory or field use.

Other key features include adjustable sampling time (100 micros to 6 s) and continuous offset of the pre-trigger light level as well as computation of luminous effective intensity based on selectable standard methods.

All essential detector data is stored in the detector’s data coupler so that any number of sensors with associated components like optical filters, integrating spheres and other input devices can be interchanged on the optometer for error free system set-up.

A wide range of UV-Vis-NIR detectors is available specifically configured for light measurement applications like intensity of medical flash heads and effective luminous intensity of strobe light warning signals or the radiant energy of pulsed Xenon sources used in UV Curing and UV processes.

Posted by Lee Mather

Follow us on Twitter

Subscribe now to Laser Focus World magazine; it's free!

Sponsored Recommendations

Precision Motion Control for Photonics: 5 Keys to Success

Aug. 30, 2024
Precision motion control is a key element in the development and production of silicon-photonic devices. Yet, when nanometers matter, it can be challenging to evaluate and implement...

Precision Motion Control for Sample Manipulation in Ultra-High Resolution Tomography

Aug. 30, 2024
Learn the critical items that designers and engineers must consider when attempting to achieve reliable ultra-high resolution tomography results here!

Motion Control Technologies for Medical Device Joining Applications

Aug. 30, 2024
Automated laser welding is beneficial in medical device manufacturing due to its precision, cleanliness, and efficiency. When properly optimized, it allows OEMs to achieve extremely...

How to Maximize Machine Building Performance with High-Performance Laser Processing

Aug. 30, 2024
Learn how an automotive high-speed laser blanking machine manufacturer builds machines that maximize throughput for faster processing speeds and improved productivity.

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!