Chemical-vapor sensor uses holographic interferometry

Sept. 1, 2005
Scientists at the University of Colorado at Boulder (Boulder, CO) have developed an interferometric approach to chemical-vapor sensing that uses dynamic holography to interrogate an array of chemically selective polymers.

Scientists at the University of Colorado at Boulder (Boulder, CO) have developed an interferometric approach to chemical-vapor sensing that uses dynamic holography to interrogate an array of chemically selective polymers.1 The interrogation of a large array of transducer elements in parallel using holography leads to what the scientists call an “odor image”a 1-D or 2-D image of the vapor response that can be analyzed using standard image-processing techniques for high-speed identification of chemical substances.

Though interferometric techniques are extremely sensitive to vapor-induced optical changes in chemically selective materials, high-quality wavefronts are needed and the susceptibility to long-term drift is high. To reduce these problems, the researchers use dynamic holography, which also allows them to look at the vapor-absorption kinetics and gain additional sensitivity for distinguishing vapors.

Their holographic interferometer uses a 532-nm laser source, designed to have a square cross section of uniform intensity. A half-wave plate and a polarizing beamsplitter cube split the beam into a reference beam and a sensing beam. The sensing beam reflects from two corners of a glass prism (using total internal reflection) in a horseshoe shape. A glass substrate with an array of polymer patches is placed on the second surface of the prism with the polymers facing away from the prism. The polymer patches are sealed inside a vapor chamber attached to the glass substrate with an o-ring, with a pair of small tubes providing a vapor inlet and outlet to the chamber. Two lenses image the plane of the polymer arrays into a photorefractive barium titanate crystal, into which the reference beam has also been sent after reflecting from a piezoelectrically controlled mirror. The sensing beam is imaged onto a CCD array and is also incident on a low-noise photodetector to make sensitivity measurements.

By arranging the polymer patches into a 3 × 3 array and subjecting them to different chemical vapors, the polymers respond to different chemicals and the image of the particular element becomes bright at the CCD (see figure). The image fades to dark again when the vapor flow establishes a steady state. In effect, the content of the vapor is recognized by analysis of its corresponding image.

The vapor-concentration sensitivity of the holographic interferometer was assessed by alternating vapor flow of various concentrations of ethyl alcohol, water, and methyl alcohol and testing the response of a poly(N-vinyl pyrrolidone) material. The chemical change of the thick polymer film has a fast surface effect and a slower bulk-diffusion effect. The vapor flow is switched between the two alcohol types and water, with clean air fed in between that serves as a reference vapor. The switching frequency is approximately 1.5 Hz; the rise time of the response is observed to be much less than 1 s. By using standard synchronous detection techniques enabled by the fast response of the interferometer, the signal-to-noise ratio of the system can be enhanced. Using a 5-s averaging time, concentration levels less than 50 parts in 106 were detected for the alcohols and water vapor.

Improving sensitivity

To further improve sensitivity, the team used an enhanced detection technique that involves rapid modulation of the phase of the reference beam and synchronous detection at the frequency of the reference modulation and at the vapor modulation frequency. In this case, concentrations could be measured down to 40 parts per billion (ppb) or 40 parts in 109 in a 5-s time period. For comparison, surface acoustic wave devices can detect at the 1- to 2-parts-per-billion level, but typically require 60 s for exposure and 100 s for recovery.

Dana Anderson, physics professor at the University of Colorado, indicates the system has not yet reached limits to sensitivity set by photon-counting noise and other fundamental considerations, so there is substantial room from improvement. He and his colleagues are working to improve sensitivity and to miniaturize the interferometer. Anderson says that the polymer-array substrate is low in cost and easily removed from and replaced on the interferometer prism, which makes the system attractive for field use where one might wish to change chemical selectivity of the device according to the task and environment.

AlphaSniffer (Boulder, CO), a company founded by Anderson and Misha Plam, president and CEO, has licensed the holographic-interferometer scheme from the University of Colorado. The company is developing an air/liquid monitor for toxic compounds in the air and bacteria and pathogens in water under an SBIR (small-business innovation research) grant from NASA. The same technology can be utilized for detection of chemical and biological warfare agents and toxic industrial compounds.

REFERENCE

1. Hongke Ye et al., Optics Letters 30(12) 1467 (June 15, 2005).

About the Author

Gail Overton | Senior Editor (2004-2020)

Gail has more than 30 years of engineering, marketing, product management, and editorial experience in the photonics and optical communications industry. Before joining the staff at Laser Focus World in 2004, she held many product management and product marketing roles in the fiber-optics industry, most notably at Hughes (El Segundo, CA), GTE Labs (Waltham, MA), Corning (Corning, NY), Photon Kinetics (Beaverton, OR), and Newport Corporation (Irvine, CA). During her marketing career, Gail published articles in WDM Solutions and Sensors magazine and traveled internationally to conduct product and sales training. Gail received her BS degree in physics, with an emphasis in optics, from San Diego State University in San Diego, CA in May 1986.

Sponsored Recommendations

Brain Computer Interface (BCI) electrode manufacturing

Jan. 31, 2025
Learn how an industry-leading Brain Computer Interface Electrode (BCI) manufacturer used precision laser micromachining to produce high-density neural microelectrode arrays.

Electro-Optic Sensor and System Performance Verification with Motion Systems

Jan. 31, 2025
To learn how to use motion control equipment for electro-optic sensor testing, click here to read our whitepaper!

How nanopositioning helped achieve fusion ignition

Jan. 31, 2025
In December 2022, the Lawrence Livermore National Laboratory's National Ignition Facility (NIF) achieved fusion ignition. Learn how Aerotech nanopositioning contributed to this...

Nanometer Scale Industrial Automation for Optical Device Manufacturing

Jan. 31, 2025
In optical device manufacturing, choosing automation technologies at the R&D level that are also suitable for production environments is critical to bringing new devices to market...

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!