Raman spectroscopy method could help diabetic patients monitor blood glucose levels without finger pricks

Aug. 16, 2010
To minimize the pain and inconvenience for  type 1 diabetics who must monitor their blood glucose levels by pricking their fingers several times a day to draw blood for testing, researchers at MIT’s Spectroscopy Laboratory are working on a non-invasive way to measure glucose levels using Raman spectroscopy.

To minimize the pain and inconvenience for type 1 diabetics who must monitor their blood glucose levels by pricking their fingers several times a day to draw blood for testing, researchers at MIT’s Spectroscopy Laboratory are working on a non-invasive way to measure glucose levels using Raman spectroscopy. The technique can reveal glucose levels by simply scanning a patient’s arm or finger with near-infrared (NIR) light, eliminating the need to draw blood.

First envisioned by Michael Feld, the late MIT professor of physics and former director of the Spectroscopy Laboratory, Raman spectroscopy identifies chemical compounds based on the frequency of vibrations of the bonds holding the molecule together.

Spectroscopy Lab graduate students Ishan Barman and Chae-Ryon Kong are developing a small Raman spectroscopy machine, about the size of a laptop computer, that could be used in a doctor’s office or a patient’s home. Such a device could one day help some of the nearly one million people in the United States, and millions more around the world, who suffer from type 1 diabetes.

Researchers in the Spectroscopy Lab have been developing this technology for about 15 years. One of the major obstacles they have faced is that NIR light penetrates only about half a millimeter below the skin, so it measures the amount of glucose in the fluid that bathes skin cells (known as interstitial fluid), not the amount in the blood. To overcome this, the team came up with an algorithm that relates the two concentrations, allowing them to predict blood glucose levels from the glucose concentration in interstitial fluid.

However, this calibration becomes more difficult immediately after the patient eats or drinks something sugary, because blood glucose soars rapidly, while it takes five to 10 minutes to see a corresponding surge in the interstitial fluid glucose levels. Therefore, interstitial fluid measurements do not give an accurate picture of what’s happening in the bloodstream.

To address that lag time, Barman and Kong developed a new calibration method, called Dynamic Concentration Correction (DCC), which incorporates the rate at which glucose diffuses from the blood into the interstitial fluid. In a study of 10 healthy volunteers, the researchers used DCC-calibrated Raman spectroscopy to significantly boost the accuracy of blood glucose measurements—an average improvement of 15%, and up to 30% in some subjects.

The researchers described the new calibration method and results in the July 15 issue of the journal Analytical Chemistry. In addition to Feld, Barman and Kong, authors include Ramachandra Rao Dasari, associate director of the Spectroscopy Lab, and former postdoctoral associate Gajendra Pratap Singh.

Michael Morris, professor of chemistry at the University of Michigan, says the group appears to have solved a problem that has long stymied researchers. “Getting optical glucose measurements of any sort is something people have been trying to do since the 1980s,” says Morris, who was not involved in this study. “Usually people report that they can get good measurements one day, but not the next, or that it only works for a few people. They can’t develop a universal calibration system.”

Morris says the noninvasive nature of Raman spectroscopy could help boost quality of life for diabetes patients, but that to be practical, any device would need to become more affordable and very simple to use. The Spectroscopy Lab researchers believe that the smaller machine they are now developing should substantially drive down costs by miniaturizing and reducing the complexity of the instrument.

Barman and Kong plan to launch a clinical study to test the DCC algorithm in healthy volunteers this fall. Their work is funded by the National Institutes of Health and National Center for Research Resources.

In October, Barman will receive the Tomas A. Hirschfeld Award at the Federation of Analytical Chemistry and Spectroscopy Societies Conference, for his work on improving spectroscopy-based glucose measurements.

Sponsored Recommendations

Optical Filter Orientation Guide

Sept. 5, 2024
Ensure optimal performance of your optical filters with our Orientation Guide. Learn the correct placement and handling techniques to maximize light transmission and filter efficiency...

Advanced Spectral Accuracy: Excitation Filters

Sept. 5, 2024
Enhance your fluorescence experiments with our Excitation Filters. These filters offer superior transmission and spectral accuracy, making them ideal for exciting specific fluorophores...

Raman Filter Sets for Accurate Spectral Data

Sept. 5, 2024
Enhance your Raman spectroscopy with our specialized Raman Filter Sets. Designed for high precision, these filters enable clear separation of Raman signals from laser excitation...

Precision-Engineered Longpass Filters

Sept. 5, 2024
Discover our precision-engineered Longpass Filters, designed for high transmission and optimal wavelength separation. Perfect for fluorescence imaging, microscopy, and more.

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!