Study uses OCT to link iris thickness to angle-closure and primary angle-closure glaucoma

Dec. 29, 2010
Increased iris thickness was associated with angle-closure and progression to glaucoma, according to a large study in Singapore.

Increased iris thickness was associated with angle-closure and progression to glaucoma, according to a large study in Singapore.

The researchers set out to gauge the relationship between quantitative iris parameters such as iris curvature, cross-sectional area and thickness, and primary open angle glaucoma.

All of the patients involved in the study underwent anterior segment optical coherence tomography (OCT) imaging. Investigators used customized software to measure iris thickness at 750 µm and 2,000 µm from the scleral spur, maximum iris thickness and cross-sectional area of the iris.

Study results showed that mean iris thickness 750 µm from the scleral spur was 0.499 mm in angle-closure eyes and 0.451 mm in normal eyes. Mean iris thickness 2,000 µm from the spur was 0.543 mm in angle-closure eyes and 0.479 mm in normal eyes. The between-group differences were statistically significant (P < .001).

Maximum iris thickness was 0.660 mm in the angle-closure group and 0.602 mm in the control group. The statistical variance was significant (P < .001).

Angle closure also correlated with age, shallow anterior chamber depth, narrower angles, smaller pupil size and female gender, according to the study authors.

The prospective study included 167 patients with angle closure and a control group of 1,153 normal participants. The group of 167 angle closure patients comprised 50 patients with primary acute glaucoma, 73 patients with primary angle closure glaucoma and 44 fellow eyes of acute primary angle closure. About 90% of the patients were of Chinese descent.

Source: British Journal of Ophthalmology

-----

Posted by Lee Mather

Follow us on Twitter

Follow BioOptics World on your iPhone

Subscribe now to BioOptics World magazine; it's free!

Sponsored Recommendations

Next generation tunable infrared lasers

Nov. 28, 2023
Discussion of more powerful and stable quantum cascade tunable infrared lasers, applications, and test results.

What AI demands mean for data centers

Nov. 28, 2023
The 2023 Photonics-Enabled Cloud Computing Summit assembled by Optica took an aggressive approach to calling out the limitations of today’s current technologies.

SLP feature for lighting control available on cameras offering

Nov. 28, 2023
A proprietary structured light projector (SLP) feature is now available on the company’s camera series, including the ace 2, boost R, ace U, and ace L.

Chroma Customer Spotlight - Dr. David Warshaw, About his Lab

Nov. 27, 2023
David Warshaw, Professor and Chair of Molecular Physiology and Biophysics at the University of Vermont (UVM), walks us through his lab. Learn about his lab’s work with the protein...

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!