Beyond OCT: human coronary artery detail in 3D

Nov. 17, 2008
BOSTON, MA, USA -- For the first time researchers are getting a detailed look at the interior of human coronary arteries, using optical frequency-domain imaging (OFDI), a technique developed at Massachusetts General Hospital. OFDI gives three-dimensional, microscopic views of significant segments of coronary arteries, visualizing areas of inflammation and plaque deposits. While optical coherence tomography (OCT) examines tissues one point at a time, OFDI can look at >1000 points simultaneously.

BOSTON, MA, USA -- For the first time researchers are getting a detailed look at the interior of human coronary arteries, using optical frequency-domain imaging (OFDI), a technique developed at the Wellman Center for Photomedicine at Massachusetts General Hospital (MGH). OFDI, reportedly an advance over optical coherence tomography (OCT), gives three-dimensional, microscopic views of significant segments of patients' coronary arteries, visualizing areas of inflammation and plaque deposits.

"This is the first human demonstration of a technique that has the potential to change how cardiologists look at coronary arteries," says Gary Tearney, MD, PhD, of the MGH Pathology Department and the Wellman Center for Photomedicine at MGH, lead author of a study describing the technique. "The wealth of information that we can now obtain will undoubtedly improve our ability to understand coronary artery disease and may allow cardiologists to diagnose and treat plaque before it leads to serious problems." The work is reported in the journal JACC: Cardiovascular Imaging.

OCT, another imaging technology developed by the MGH investigators, examines tissues one point at a time -- while OFDI can look at more than 1,000 points simultaneously using a device developed at MGH-Wellman. Inside a fiberoptic probe, a constantly rotating laser tip emits a light beam with an ever-changing wavelength. As the probe moves through the structure to be imaged, measuring how each wavelength is reflected back allows rapid acquisition of the data required to create the detailed microscopic images. Besides providing three-dimensional images of an artery's microstructure in seconds, the increased speed also reduces signal interference from blood, which had plagued the first-generation technology. In 2006 members of the MGH-Wellman team reported the successful use of OFDI to image the esophagus and coronary arteries of pigs.

The current study enrolled three patients scheduled to have stents placed in their coronary arteries at the Lahey Clinic in Burlington, Mass. After the completion of stent placement, OFDI was used to image 3- to 7-centimeter-long segments of the patients' coronary arteries including the stented areas. OFDI provided detailed images along the length of the arteries -- visualizing lipid or calcium deposits, immune cells that could indicate inflammation, and the stents -- and dramatic "fly-through" views looking down the artery's interior. More detailed, cross-sectional images of narrowed vascular segments revealed features associated with the type of atherosclerotic plaques that are likely to rupture and cause a heart attack.

Tearney and his colleagues note that these findings need to be duplicated in a larger group of patients, and the time required to process the "fly-through" images -- currently several hours -- needs to be reduced to provide the real-time information most useful for clinical applications. Combining OFDI with intravascular ultrasound might help with another of the technique's limitations, the inability to penetrate deep into tissues.

"While more work remains, the technology is advancing at a rapid pace. We expect to see commercial devices available in a one- to two-year time frame," says Brett Bouma, PhD, of the Wellman Center, senior author of the report. "Our goal now is to help put the pieces in place to ensure that this technique will be widely available to interventional cardiologists." Bouma is an associate professor of Dermatology, and Tearney an associate professor of Pathology at Harvard Medical School.

The MGH has licensed cardiovascular applications of OFDI to Terumo Corporation, which has supported nonclinical OFDI studies by Tearney and Bouma.

More information:
Massachusetts General Hospital

Sponsored Recommendations

On demand webinar: Meet BMF’s first hybrid resolution printer, the microArch D1025

July 26, 2024
Join us in this webinar to explore our newest product release - the microArch D1025 - our first dual-resolution printer. Learn more!

Meet the microArch D1025: Hybrid Resolution 3D Printing Technology

July 26, 2024
Meet BMF's newest release, our first dual-resolution printer for the prototyping and production of parts requiring micron-level precision.

Optical Power Meters for Diverse Applications

April 30, 2024
Bench-top single channel to multichannel power meters, Santec has the power measurement platforms to meet your requirements.

Request a quote: Micro 3D Printed Part or microArch micro-precision 3D printers

April 11, 2024
See the results for yourself! We'll print a benchmark part so that you can assess our quality. Just send us your file and we'll get to work.

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!