Low-cost VCSEL swept source for OCT relies on self-heating, needs no MEMS

Feb. 22, 2017
A vertical-cavity surface-emitting laser (VCSEL)-based, wavelength-swept laser source for optical coherence tomography (OCT) is both simple and low in cost.
Content Dam Lfw Print Articles 2017 02 1702lfw Nb F5
Content Dam Lfw Print Articles 2017 02 1702lfw Nb F5
Content Dam Lfw Print Articles 2017 02 1702lfw Nb F5
Content Dam Lfw Print Articles 2017 02 1702lfw Nb F5
Content Dam Lfw Print Articles 2017 02 1702lfw Nb F5

A vertical-cavity surface-emitting laser (VCSEL)-based, wavelength-swept laser source for optical coherence tomography (OCT) developed by researchers at Kookmin University (Seoul, South Korea) and Chosun University (Gwangju, South Korea) is both simple and low in cost. The self-heating sweep VCSEL (SS-VCSEL) is frequency-swept through direct ramped modulation of the laser pulses, which causes a self-heated temperature sweep in the laser and produces the desired wavelength sweep. This approach is very different from other VCSEL OCT sources that require a moving microelectromechanical systems (MEMS) mirror—instead, the SS-VCSEL is actually a stock low-cost (around $100) VCSEL designed for telecom use at 1300 nm and needs only modulation electronics.

The researchers first evaluated the self-heating effect in the VCSEL as a function of modulation rate and duty cycle, and figured out that the maximum effective sweep rate was between 10 and 100 kHz. The full sweep bandwidth was 10 nm, which would result in an axial resolution of 135 μm in air for an OCT system and a full range of more than 10 cm—over 740 times the resolution, and suitable for long-range OCT imaging. The current pulses consisted of a separated sawtooth shape and an added DC bias adjusted to lead to a 50% duty cycle. An interferometric SS-OCT system was used to further characterize the swept source, showing that the tuning speed got faster toward the end of each sweep, which the researchers think is a result of a rise in the heating rate as the temperature increases. Next, OCT images of a human fingertip and a glass plate were taken to a 5 mm depth, showing good results. Reference: S. Moon and E. S. Choi, Biomed. Opt. Express, http://dx.doi.org/10.1364/boe.8.001110 (Jan. 25, 2017).

About the Author

John Wallace | Senior Technical Editor (1998-2022)

John Wallace was with Laser Focus World for nearly 25 years, retiring in late June 2022. He obtained a bachelor's degree in mechanical engineering and physics at Rutgers University and a master's in optical engineering at the University of Rochester. Before becoming an editor, John worked as an engineer at RCA, Exxon, Eastman Kodak, and GCA Corporation.

Sponsored Recommendations

Melles Griot® XPLAN™ CCG Lens Series

March 19, 2024
IDEX Health & Science sets a new standard with our Melles Griot® XPLAN™ CCG Lens Series fluorescence microscope imaging systems. Access superior-quality optics with off-the-shelf...

Spatial Biology

March 19, 2024
Spatial Biology refers to the field that integrates spatial information into biological research, allowing for the study of biological systems in their native spatial context....

Custom-Engineered Optical Solutions for Your Application

March 19, 2024
We combine advanced optical design and manufacturing technology, with decades of experience in critical applications, to take you from first designs to ongoing marketplace success...

Semrock Optical Filters Resources

March 19, 2024
Looking for more information about Semrock optical filters? Explore sets by fluorophore, download the 2023 Semrock catalog and more.

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!