Buried waveguides may improve microbioanalysis

Dec. 1, 2003
Researchers at National Cheng Kung University and Southern Taiwan University (both of Tainan, Taiwan) have developed several techniques that may make a promising microchip bioanalytical technology practical.

Researchers at National Cheng Kung University and Southern Taiwan University (both of Tainan, Taiwan) have developed several techniques that may make a promising microchip bioanalytical technology practical. These include improved control of samples through the chip using electrophoresis, hydrodynamic control, and robust channel coating; integration of a DNA amplification chamber; and enhanced, easily-aligned optical detection without the need for expensive on-chip electronics.

The new work involves a cytometer, which effectively counts the number of particles (cells) in a sample; and electrophoresis-based separation of fluorescently-tagged specimens, in which an electric field moves different species at different rates, allowing them to be differentiated. Both devices require microchannels through which the sample and buffer solution can flow, electrodes to pull the individual specimens forward, a light source to illuminate the sample, and an efficiently coupled detector. In the cytometer, the detector senses when light is blocked by passing particles. In the electrophoresis chip, fluorescent emissions are picked up to show the relative positions of tagged species.

Until now, one of the biggest problems has been detecting this signal light. In principle, building microsystems to detect or transport the optical signal from the sample is not difficult. In practice, however, it has been difficult to build a system that is efficient and high in resolution without being expensive. The new system is not only cheap in terms of its constituent parts, but has only one manual alignment step—insertion of a fiber into a self-aligning channel.

The buried-waveguide system involves the sandwiching of two low-cost glass substrates, each with identical grooves etched into them, one set for the waveguiding channel and another for the sample flow. The sample channel is orthogonal to the waveguiding channel (which it interrupts). Once these have been aligned, bonded, and fused, the waveguiding microchannel is filled via microcapillary action with a spin-on-glass material and then removed by a vacuum. A coating is left that has two functions: improving the optical surface of the channel, and acting as a cladding layer that provides a high-refractive-index change between core and cladding.

To get light into and out of the system, the ends of two optical fibers were etched so that they would fit into the end of the waveguiding microchannels. The channel is then filled with the core material—SU-8 negative photoresist—to produce the finished optical waveguide. In this way, the sample can be directly interrogated by an off-chip light source, the result of which is read out by an off-chip detector.

In this flow cytometer, optical fibers (bluish transparent objects at top and bottom) bring light into and out of the device. A sample is injected through the middle inflow on the left, while guiding liquids are injected through those on either side. As they mix in the channel, the sample is focused into a narrow centered beam. The light comes through the top optical fiber and is absorbed (or not) by the channel; the resulting signal leaves via the bottom fiber. Electrophoresis electrodes are switched high and low to pull the sample along the length of the channel, where it emerges through the end outflow.

For better separation of DNA using electrophoresis, the sample channel was coated with the same spin-on glass as the waveguiding channel. The smoother surface made for better, cleaner flow, and prevented species "bunching." Also, as well as building the electrophoresis electrodes into a third layer of the glass sandwich, the team devised an on-chip heater and temperature sensor for the polymerase chain-reaction (PCR) chamber (where a single DNA strand can be duplicated, effectively amplifying the signals it produces). This temperature control is vital for PCR to take place efficiently. Finally, the team has been working on the shape of the sample channels. The inflow has now been designed so that the sample is effectively focused in the center of the channel by the liquid around it (see figure).

REFERENCE

  1. Che-Hsin Lin et al., Sensors and Actuators A: Physical 107, 125, 2003.
About the Author

Sunny Bains | Contributing Editor

Sunny Bains is a contributing editor for Laser Focus World and a technical journalist based in London, England.

Sponsored Recommendations

Request a quote: Micro 3D Printed Part or microArch micro-precision 3D printers

April 11, 2024
See the results for yourself! We'll print a benchmark part so that you can assess our quality. Just send us your file and we'll get to work.

Request a free Micro 3D Printed sample part

April 11, 2024
The best way to understand the part quality we can achieve is by seeing it first-hand. Request a free 3D printed high-precision sample part.

How to Tune Servo Systems: The Basics

April 10, 2024
Learn how to tune a servo system using frequency-based tools to meet system specifications by watching our webinar!

Precision Motion Control for Sample Manipulation in Ultra-High Resolution Tomography

April 10, 2024
Learn the critical items that designers and engineers must consider when attempting to achieve reliable ultra-high resolution tomography results here!

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!